| Name | DR:T6A_D123_971703 |
|---|---|
| Type | DR:T6A |
| Description | External door part of a window unit |
| Location | 123 |
| Serial Number | n/a |
| Installation Date | 2019-05-26 |
| Warranty Start Date | 2019-10-01 |
| Tag Number | n/a |
| BarCode | n/a |
| Asset ID | DR:T6A-123,128-DR:T6A_D123_971703 |
| Comments | Part of a window casement. See window schedule for structural opening | n/a |
|---|---|---|
| Door Panel Height | 2135 mm | n/a |
| Door Panel Thickness | 52 mm | n/a |
| Door Panel Width | 826 mm | n/a |
| FireClass | n/a | n/a |
| FireRating | n/a | n/a |
| Frame Type | F1 | n/a |
| FrameFinish | SS | n/a |
| FrameMaterial | Steel | n/a |
| GlassType | n/a | n/a |
| HardwareSet | SHW-25 | n/a |
| HeadDetail | H-3 | n/a |
| JambDetail | J-2 | n/a |
| OPENumber | 132-R | n/a |
| SecurityRating | 1123 | n/a |
| SillDetail | S-14 | n/a |
| Step | Description | Expected Duration |
| 1 | Check to ensure that doors and frame have not settled out of true. | 1.0 minute |
| 2 | Doors should be free of dents and scratches and they should open freely. | 1.0 minute |
| 3 | Openings should be kept clear of obstructions (internal and external) to ensure that doore operation is not impeded. | 1.0 minute |
| 4 | The locks and/or panic hardwer should be checked to ensure smooth and correct operation and if necessary adjustments should be made (e.g. tightening of screws). | 5.0 minute |
| 5 | If the ironmongery is inoperable for any reason then contact manufacturer directly for assitance. | 10.0 minute |
| Step | Description | Expected Duration |
| 1 | Hinges should be inspected periodically for wear that may inhibit the free movement of the door and also that may cause the door to drop. All screws should be checked for tightness. | 5.0 minute |
| 2 | Loosening of hinges is usually caused by poor alignment when fitting the door. Loose screws should be tightened and the problem should be eliminated by realigning the hinges. | 10.0 minute |
| 3 | Hinges should be lubricated periodically with silicone based grease. Whilst squeaking of hinges is a sign of lack of lubrication, if it occurs frequently then the pin misalignment should be investigated. | 10.0 minute |
| 4 | Whether supplied in satin or polished finish, stainless steel should be dusted regularly, occasionally washed with warm soapy water and dried with a soft clean cloth. Avoid acid or chloride based cleaning products and abrasive materials. Greasing over all exposed stainless steel once cleaned is a necessity. | 5.0 minute |
| Guarantor Parts | info@Gallifordtry.co.uk |
|---|---|
| Duration Parts | 1.0 year |
| Guarantor Labor | info@Gallifordtry.co.uk |
| Duration Labor | 9.0 year |
| WarrantyDescription | Standard one-year "call back" warranty |
| Name | DR:T6A |
|---|---|
| Category | Pr_30_59_24_52 : Metal doorsets |
| Description | External door part of a window unit |
| Asset Type | Fixed |
| Manufacturer | sales@lathamssteeldoors.co.uk |
| Model Number | Glazed Steel Door (Security) (video search) |
| Reference | 08 11 69 - METAL STORM DOORS 02/10 |
| Material | Steel |
| Function | 1 | n/a |
|---|
| Name | Description | Stage | Type |
|---|---|---|---|
| Warranty Certificate | O&M Data | Submitted | Certificates |
| Installation Instructions | O&M Data | Submitted | Manufacturer Instructions |
| Operations and Maintenance Instructions | O&M Data | Submitted | Operation and Maintenance |
| Product Data | External door part of a window unit | Submitted | Product Data |